Cedara I-Connect™ Components & Contents

All the Features and Components that You'll Need

Cedara I-Connect has a full compliment of components and services for DR acquisition.

Application
The application provides the UI that allows the user (operator) to interact with the system. The operator is guided through a natural workflow that allows fast and complete acquisition.

Acquisition Service
The acquisition service controls the connected hardware devices using the acquisition parameters passed from the main application and sends back the acquired images to the application.

MWL Service
The MWL service obtains the list of examination procedures scheduled for the acquisition console from the HIS/RIS.

MPPS Service
The MPPS service talks to the HIS/RIS in order to complete the IHE scheduled workflow profile (SWF). Its role is to send information about the procedures performed at the acquisition console back to HIS/RIS.

Archive Service
Once the acquisition session is completed all images are scheduled to be automatically sent to configured archive(s). The archive service immediately sends images to the archive. At the end it triggers the storage commitment service. In addition to automatic archiving, the operator can send arbitrary sets of images to any of the configured DICOM storage nodes.

Storage Commitment Service
The storage commitment service requests from the archive confirmation that all sent images are "committed", i.e. stored safely. Once images are committed they became subject for removal (in the case of low storage condition).

SMA Service
The single media archive (SMA) service allows the operator to burn arbitrary sets of images on CD/DVDs. A DICOM CD viewer is appended to the media so the images can be viewed later.

Print Service
The operator will have the option to print images to configured Windows or DICOM printers.

What's in the Platform

Click on a subhead for details:

  • Reference Implementation User Interface
    • Designed for touch-screen operation
    • Support for 15" touch-screen in 1024x768 resolution
    • Support for 17" touch-screen in 1200x900 resolution
  • Reference Implementation Workflows
    • Scheduled exam
    • Unscheduled exam
    • Emergency (trauma) exam
    • Protocol-based exam
    • Suspended exam
    • Acquisition
    • Basic QC Review
    • Image Stitching&dagger
    • Printing
    • Single media archive
    • Wet Read
  • Acquisition
    • Patient worklist display
    • Trauma/emergency study suspend mode
    • Local and Network Modality Worklist Query
    • New patient entry
    • Manual patient information update
    • Acquisition protocol selection
    • Automatic step-through acquisition
    • Study suspend mode
    • Study accept/reject
    • Study auto-send (DICOM)
    • Integrated on-screen detector controls
    • Integrated on-screen generator controls
  • Review Tools
    • Window width and level
    • Zoom
    • Pan
    • Magnify
    • Line measurements
    • Grayscale invert
    • Cobb angle
    • Annotations
    • Flip and rotate
    • Orientation markers
    • Saving of presentation state
    • Semi-automated image stitching
  • Print Export Module
    • Automatic printing
    • Interactive print layout controls
    • GDI Printing
    • DICOM Film Print
    • Patient CD/DVD Burning with on-disk viewer
  • Workflow Control
    • Acquisition and processing protocol
    • Modality/procedure specific acquisition and processing protocols
    • Automatic local store purge
  • Integrated Image Processing
    • Protocol-regulated image processing
    • Image Enhancement
    • Auto-Window Width and Level
    • Auto-Shutter
    • Exposure Index Calculation
  • DICOM Interface
    • Concurrent/background DICOM Send
    • DICOM Storage Commitment
    • DICOM Modality Performed Procedure Step (MPPS)
    • DICOM Part-10 directory (DICOMDIR) export for Patient Media function.
  • Service Tools
    • Acquisition protocol set-up and edit
    • User preferences configuration set-up
    • In the field rebranding
    • In the field localization
    • IP Remote-access capable (via WebEx/Windows Remote Desktop, LogMeIn Rescue)
  • Logs
    • Centralized system log
    • HIPAA-compliant patient information access log
  • Roles
    • Operator
    • Service Technician
  • Hardware Software Developer Kit
    • Test Harness
    • Sample Simulator
    • Interface specification
  • Reference Implementation Hardware
    • Varian 4343R integration

More Information

> Overview
> Sample Images
> Trial Version
> Product Sheet
> Cedara xPipe™
> Cedara OpenEyes™

† Image Stitching is an optional feature.
The OEM Integrator assumes regulatory responsibility for the fully integrated system.


Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries.
Varian is a trademark or registered trademark of Varian Medical Systems, Inc. in the United States and other countries.